Mass Spectrometers

Matrix Assisted Laser Desorption Time of Flight Mass Spectrometer(MALDI TOF MS)

Instrument specification:

MALDI technique is a soft ionization method used to study most of the biomolecules like proteins, DNA so on. Apart from bio molecules other organic and inorganic samples can also be analyzed. Here in our instrument MALDI was coupled with TOF technique. Here is the link to know more about MALDI and TOF technique.

http://www.abrf.org/ABRFNews/1997/June1997/jun97lennon.html
http://www.rmjordan.com/Resources/Tutorial.pdf

Instrument specification:

MALDI technique is a soft ionization method used to study most of the biomolecules like proteins, DNA so on. Apart from bio molecules other organic and inorganic samples can also be analyzed. Here in our instrument MALDI was coupled with TOF technique. Here is the link to know more about MALDI and TOF technique.

Our instrument equipped with

  1. 337 nm Nitrogen laser for desorption and ionization
  2. TOF having linear and reflectron mode of detection
  3. Delayed extraction of ions

Theory and how it works

The Voyager-DE™ PRO Biospectrometry™ Workstation is equipped with a reflecting ion mirror that boosts the resolution and mass accuracy over a large mass range. Post-source decay or PSD experiments are facilitated by the new Voyager Version 5 with Data Explorer™ software. Obtain even more structural information with the collision-induced dissociation (CID) option for enhanced fragmentation.

Schematic of sample inside the sample compartment. LASER desorbing and ionizing the sample embedded on matrix. The ions are flying towards the detector through field free region.

Block diagram of instrument.

Key Features:

  1. High-performance benchtop Matrix-Assisted Laser Desorption Ionization Time-of-Flight (MALDI- TOF) system for high quality data
  2. Powerful Voyager Version 5 Software with Data Explorer™ for flexible acquisition and data processing
  3. Reflectron provides high mass accuracy and post-source decay (PSD)
  4. Fully automated acquisition and processing of data provides needed throughput
  5. Integrated Microsoft® Visual Basic , for Applications (VBA) permits macro recording and customized processing routines
  6. Collision-induced dissociation (CID) provides more structural information

Results

LDI mass spectrum of MoS2 nanoflakes in the negative mode. Inset: Experimental spectrum taken from nanoflakes (a) shows the expected isotope distribution for Mo13S25-(b). (Adopted from Singh, D. M. D. J.; Pradeep, T.; Bhattacharjee, J.; Waghmare, U. V. J. Phys. Chem. A.; 2005; 109 (33); 7339-7342.) Highlighted in cover page

Balzers Thermostar

Balzers Thermostar

Instrument Specification: Mass range : 1-300 amu,
Resolution : 0.1,
Capillary : Quartz,
Source : Open ion source,
Turbo pump : 65 L/s

Read more
Desorption Electrospray Ionization (DESI) Mass Spectrometer

Desorption Electrospra...

The LTQ XL is a high resolution linear ion trap mass spectrometer. The ionization can be done here by three different methods; electrospray ionization (ESI), atmospheric pressure

Read more
Gas Chromatograph Mass Spectrometer

Gas Chromatograph Mass...

The GCMS (Gas Chromatograph Mass Spectrometer) instrument is mainly consists of two parts, namely GC part (Clarus 680) and MS part (Clarus 600 C).

Read more
ICP-MS

ICP-MS

ICP-MS is a type of mass spectrometry which is capable of detecting metals and several non-metals at concentrations as low as part per trillion.

Read more
Mass spectrometers

Mass spectrometers

MALDI technique is a soft ionization method used to study most of the biomolecules like proteins, DNA so on. Apart from bio molecules other organic and inorganic samples can also be analyzed.

Read more
Q Exactive Ultra High Mass range (UHMR) Hybrid Quadrupole-Orbitrap mass spectrometer

Q Exactive Ultra High ...

The Thermo Scientific Q Exactive UHMR hybrid Quadrupole-Orbitrap mass spectrometer combines in-source trapping, high-performance quadrupole precursor ion selection, a higher-energy collisional dissociation (HCD) cell, and a high-resolution, accurate-mass (HRAM) Orbitrap mass analyzer, with optimized RF voltages for improved high mass ion transmission to provide unrivaled sensitivity and resolution in the ultra-high mass range.

Read more
QTRAP

QTRAP

The 3200 Q TRAP LC/MS/MS System is a high performance hybrid triple quadrupole linear ion trap LC/MS/MS mass spectrometer.

Read more
SYNAPT

SYNAPT

SYNAPT G2-Si uses high efficiency T-Wave ion mobility with high performance tandem MS to significantly enhance the peak capacity, specificity and sensitivity of analysis.

Read more